Filters
Year Range
20102025
2010
2015
2020
2025
Difficulty
Session
Variant
Sub-topic
71 questions
Physics/Paper 1/Measurement Techniques
CAIEAS Level9702-as · Paper 1

Measurement Techniques

71 questions· page 1 of 8

Q272024 Oct/Nov·P121MEasy

What could describe the time-base of a cathode-ray oscilloscope (CRO)?

Options

A   the frequency per division on the screen
B   the number of divisions on the screen per unit frequency
C   the number of divisions on the screen per unit time
D   the time per division on the screen

Similar questions
Q202023 May/Jun·P111MMedium-Easy

In an experiment, a student uses a microphone and a cathode-ray oscilloscope (CRO) to analyse a sound wave. The diagram shows the trace on the screen of the CRO.

The student is expecting a sinusoidal waveform to be shown on the screen.

Which changes should the student make to the time-base and the yy-gain of the CRO so that the screen shows a continuous trace for one complete cycle of the waveform?

Options

time-basey-gain
Adecreasedecrease
Bdecreaseincrease
Cincreasedecrease
Dincreaseincrease
Similar questions
Q212022 Feb/Mar·P121MMedium-Easy

A cathode-ray oscilloscope (CRO) is used to determine the frequency of a sound wave.
The diagram shows the waveform on the screen.
The time-base setting is 5.0 ms div15.0\text{ ms div}^{-1}.

What is the best estimate of the frequency of the sound wave?

Options

A   50 Hz50\text{ Hz}
B   71 Hz71\text{ Hz}
C   100 Hz100\text{ Hz}
D   143 Hz143\text{ Hz}

Similar questions
Q42021 Feb/Mar·P121MMedium-Easy

A micrometer screw gauge is used to measure the diameter of a copper wire.

The reading with the wire in position is shown in diagram 1. The wire is removed and the jaws of the micrometer are closed. The new reading is shown in diagram 2.

What is the diameter of the wire?

Options

A   1.95 mm1.95\ \text{mm}
B   2.45 mm2.45\ \text{mm}
C   2.59 mm2.59\ \text{mm}
D   2.73 mm2.73\ \text{mm}

Similar questions
Q42021 May/Jun·P111MMedium-Easy

A signal of frequency 25 Hz25\ \text{Hz} is displayed on the screen of a cathode-ray oscilloscope.

What is the time-base setting?

Options

A   10 ms cm110\ \text{ms cm}^{-1}
B   20 ms cm120\ \text{ms cm}^{-1}
C   25 ms cm125\ \text{ms cm}^{-1}
D   40 ms cm140\ \text{ms cm}^{-1}

Similar questions
Q52021 May/Jun·P111MMedium-Easy

A micrometer screw gauge is used to measure the diameter of a wire.

The reading on the micrometer with the jaws closed is (0.05±0.02) mm(-0.05 \pm 0.02)\ \text{mm}.

The reading with the wire in position between the two jaws is (+1.03±0.02) mm(+1.03 \pm 0.02)\ \text{mm}.

What is the diameter of the wire?

Options

A   (0.98±0.02) mm(0.98 \pm 0.02)\ \text{mm}
B   (1.08±0.02) mm(1.08 \pm 0.02)\ \text{mm}
C   (0.98±0.04) mm(0.98 \pm 0.04)\ \text{mm}
D   (1.08±0.04) mm(1.08 \pm 0.04)\ \text{mm}

Similar questions
Q42021 May/Jun·P121MMedium-Easy

An analogue ammeter with a range of 00250 mA250\text{ mA} is connected into an electrical circuit. The diagram shows the ammeter’s display.

What is the reading on the ammeter?

Options

A   76 mA76\text{ mA}
B   165 mA165\text{ mA}
C   183 mA183\text{ mA}
D   190 mA190\text{ mA}

Similar questions
Q42021 May/Jun·P131MMedium-Easy

The diagram shows two readings on a micrometer.

What is the difference between the two readings?

Options

A   10.34 mm10.34\text{ mm}
B   11.84 mm11.84\text{ mm}
C   12.34 mm12.34\text{ mm}
D   12.84 mm12.84\text{ mm}

Similar questions
Q12021 Oct/Nov·P131MMedium-Easy

A paperback book contains 210 sheets of paper (pages). Its thickness is measured with a ruler, as shown.

What is the average thickness of one sheet of the paper in the book?

Options

A   0.013 mm
B   0.017 mm
C   0.13 mm
D   0.17 mm

Similar questions
Q42020 Feb/Mar·P121MMedium-Easy

A transmitter emits a pulse of electromagnetic waves towards a reflector. The pulse is reflected and returns to the transmitter.

A detector is located at the transmitter. The emitted pulse and the reflected pulse are displayed on a cathode-ray oscilloscope (CRO) as shown.

The pulse takes 6.3μs6.3\,\mu\text{s} to travel from the transmitter to the reflector.

What is the time-base setting of the CRO?

Options

A   2.1μs cm12.1\,\mu\text{s cm}^{-1}
B   3.2μs cm13.2\,\mu\text{s cm}^{-1}
C   4.2μs cm14.2\,\mu\text{s cm}^{-1}
D   6.3μs cm16.3\,\mu\text{s cm}^{-1}

Similar questions